Z-0089-2021: Rashkind Balloon Septostomy Catheter, 4F, Closed end, 50 cm, Pediatric, Single Lumen Product number: 0071

Recall record Z-0089-2021 for Medtronic Vascular. View source facts, labeled dates, and the original FDA record.

FDA identifier
Z-0089-2021
Company in FDA record
Medtronic Vascular
FDA classification date
Oct 16, 2020
First observed by MedTech Watch
Nov 16, 2026
Latest observed content change
Nov 16, 2026
Recall classification
Class I

Reason stated in the source

Subsequent failure of catheters in the field and failed quality testing

Source facts

Action
An immediate field corrective action was initiated by Medtronic field representatives. Customers were notified verbally to quarantine and return affected product on 25-Aug-2020. The following information was verbally provided to affected customers by Medtronic representative: "A supplier for Rashkind Catheter product has notified Medtronic that it has shipped product to Medtronic that may contain an issue. The supplier conducts a routine test in production. In two separate lots, the manufacturing specification was not met by all samples, but the lots were inadvertently shipped to Medtronic. We are requesting that you immediately refrain from using this product and place it in quarantine until further notice. You will be receiving an official recall notice with instructions for product return. Your Sales Representative will assist you with this process. We apologize for the inconvenience; however this action is necessary to ensure the utmost patient safety with the use of our products" In the United States on 09-Sep-2020, Medtronic began delivering an "Urgent Medical Device Recall" letter via UPS 2- day delivery to risk managers who, according to Medtronic records have received affected product. The notification states the following: 1. Identify and quarantine all unused Rashkind Balloon Catheters as listed in notification 2. Return all unused affected product in your inventory to Medtronic. Contact Medtronic Customer Service at 1-888-283-7868 to initiate a product return. Your local Medtronic Representative can assist you in the return of this product. 3. Please complete the enclosed Customer Confirmation Form and email to RS.CFQFCA@medtronic.com. Even if you do not have any product to return 4. Please forward the notice to all those who need to be aware within your organization.
Initiated
2020-08-25
Root cause
Device Design
Terminated
2024-04-04
Distribution
Worldwide Distribution: USA (nationwide) states of: MA, PA, TN, IN, MI, WA, CA, CO, AZ, NC; and OUS countries of: Algeria, Armenia, Australia, Austria, Barbados, Belgium, Bulgaria, Canada, Croatia, Czech Republic, Finland, France, French Polynesia, Germany, Greece, Hungary, India, Ireland, Israel, Italy, Japan, Latvia, Lebanon, Macedonia, Malaysia, Martinique, Moldova, Morocco, Netherlands, New Caledonia, New Zealand, Norway, Oman, Paraguay, Poland, Portugal, Puerto Rico, Romania, Saudi Arabia, Serbia, Singapore, Slovakia, Slovenia, South Africa, Spain, Sweden, Switzerland, Tanzania, Tunisia, United Arab Emirates, and United Kingdom.
Recall number
Z-0089-2021
Recall status
Terminated
CDRH record ID
183686
FDA classified
2020-10-16
Recall event number
86381

Source facts and excerpts are reproduced for research. Dates retain their source meanings. “First observed” describes collection, not FDA publication or product launch.

Recall classification is supplied only when the recall number matches an enforcement record. Recall class and device class are different fields. Several recall records may belong to one recall event.

Useful context

Device classifications

FDA dataset:

Last successful check: Nov 22, 2026

Source classifications may change.

510(k) clearances

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset monthly.

Recall records

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset weekly.

Keep this research moving.

Follow ten competitors and ten product codes. Get matching changes in your dashboard and a weekly brief, for $49/month.

Start a 14-day free trial ↗