Skip to content

Public FDA record

Z-0095-2023: BD Vacutainer Tube Sodium Fluoride: 100 mg, Potassium Oxalate: 20 mg, Catalog Number 367001. For collecti

Recall record Z-0095-2023 for Becton Dickinson & Company. View source facts, labeled dates, and the original FDA record.

FDA identifier
Z-0095-2023
Company in FDA record
Becton Dickinson & Company
FDA classification date
Oct 14, 2022
First observed by MedTech Watch
Nov 16, 2026
Latest observed content change
Nov 16, 2026
Recall classification
Class II

Reason stated in the source

The affected product contains isobutylene which has recently demonstrated potential interference in determination of methanol by gas chromatography methods. The interference may lead to false positive results in methanol testing.

Source facts

Action
On September 15, 2022, the firm notified affected distributors and customers of the recall via Urgent Medical Device Product Advisory letters. Customers were instructed to do the following: 1. Inspect your inventory for the affected catalog number. 2. Ensure the contents of the Product Advisory are read, understood and shared with laboratory management staff having oversight over gas chromatography testing for methanol. Review internal method validations, and if applicable, adjust test practices or settings to avoid potential interference (e.g., implementing the tube as a blank/control, adjustment of GC column and/or operational settings to prevent co-elution, or conversion to dual-column system). 3. If the potential interference cannot be mitigated, stop using the BD Vacutainer Tube Sodium Fluoride: 100 mg, Potassium Oxalate: 20 mg. Product may be returned for credit. The recalling firm will update the IFU to address the potential risk of interference from rubber stopper outgassing in gas chromatography methods. The firm has also initiated corrective and preventive action to investigate root cause and identify actions. If you have further questions, please contact the firm via Phone: 1-844-8BD-LIFE (1-844-823-5433) Say Recall when prompted Mon Fri 8:00am and 5:00pm CT or Email: productcomplaints@bd.com
Initiated
2022-09-15
Root cause
Component design/selection
Distribution
Distribution US nationwide, Canada, New Zealand, and Hong Kong.
Recall number
Z-0095-2023
Recall status
Open, Classified
CDRH record ID
195971
FDA classified
2022-10-14
Recall event number
90824

Source facts and excerpts are reproduced for research. Dates retain their source meanings. “First observed” describes collection, not FDA publication or product launch.

Recall classification is supplied only when the recall number matches an enforcement record. Recall class and device class are different fields. Several recall records may belong to one recall event.

Useful context

Device classifications

FDA dataset:

Last successful check: Nov 22, 2026

Source classifications may change.

510(k) clearances

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset monthly.

Recall records

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset weekly.

Keep this research moving.

Follow ten competitors and ten product codes. Get matching changes in your dashboard and a weekly brief, for $49/month.

Start a 14-day free trial ↗