Open original FDA record ↗Recall record
- FDA identifier
- Z-0096-2021
- Company in FDA record
- Handicare AB
- FDA record creation date
- Oct 9, 2020
- First observed by MedTech Watch
- Nov 16, 2026
- Latest observed content change
- Nov 16, 2026
- Recall classification
- Class II
Reason stated in the source
Carry bar may detach during use of mobile lifts and ceiling lifts equipped with the Swifthook component.
Source facts
- Action
- Handicare USA issued an field safety notification on August 21, 2020. It states the following. Users of affected units are urgently requested to perform the following actions for devices in their possession without delay upon receiving the field notice. It is advised to cease using the Swifthook. Instead, the carry bar can be mounted directly onto the mobile or ceiling lift. This action will eliminate the possibility of incorrectly mounting the Swifthook while gaining the advantage of increased lift height capacity. The Swifthook should be destroyed. 1. Remove the Swifthook from the carry bar using the appropriate Allen key (5 mm) and wrench (13 mm); 2. Remove the fasteners from the mobile lift's boom using two 13 mm wrenches. In the case of a ceiling lift, remove the fasteners from the ceiling lift's H-adapter using two 4 mm Allen Keys; 3. Attach the carry bar directly to the mobile lift's boom. Check that the lock nuts are undamaged and still offers resistance to tightening by hand, and if not, replace with new nuts (DIN985 M8fzb lock nut). In the case of a ceiling lift, use two 4 mm Allen Keys and tighten well by hand. Each customer is required to communicate the content of the field safety notice to all end users and complete the response form, which shall be returned by email to Handicare USA using provided contact details no later than September 28, 2020. For any questions regarding this FSN, please contact FieldAction.NorthAmerica@handicare.com or Laren Mcintosh, Director of Quality, North America.
- Initiated
- 2020-08-21
- Root cause
- Use error
- Terminated
- 2023-01-30
- Distribution
- Worldwide distribution - US Nationwide distribution including in the states of CA, IL, MD, MI, MN, NH, NJ, NY, ON, PA, TX, VA, WA, WI and the countries of Australia, Belgium, Canada, Chile, Denmark, Finland, Germany, Iceland, Ireland, Israel, Japan, Lithuania/ Lathvia, Malaysia, New Zealand, Norway, Poland, Portugal, Qatar, Saudi Arabia, Spain, Sweden, Taiwan the Netherlands, UAE, UK.
- Recall number
- Z-0096-2021
- Recall status
- Terminated
- CDRH record ID
- 183334
- FDA record created
- 2020-10-09
- Recall event number
- 86318