Skip to content

Public FDA record

Z-0470-2022: RefleXion Medical Radiotherapy System - System Label: "*** refleXion REF RXM1000 ***" Physics Guide/Tr

Recall record Z-0470-2022 for Reflexion Medical, Inc.. View source facts, labeled dates, and the original FDA record.

FDA identifier
Z-0470-2022
Company in FDA record
Reflexion Medical, Inc.
FDA record creation date
Jan 10, 2022
First observed by MedTech Watch
Nov 16, 2026
Latest observed content change
Nov 16, 2026
Recall classification
Class II

Reason stated in the source

Due to dose discrepancy when delivering a plan to a patient in a Non-HFS (Head First Supine) orientation specifically in Feet First Supine (FFS).

Source facts

Action
On 11/24/2021 and 12/02/2021, the firm emailed customers to inform them of an ongoing investigation a potential dose discrepancy while treating patients in an orientation other than Head First Supine (HFS), i.e., Feet First Supine (FFS) and Head First Prone (HFP) and Feet First Prone (FFP). On 12/22/2021, the firm sent an "Urgent Safety Notification" letter to customers informing them that the Recalling Firm has confirmed that a dose discrepancy exists for patients treated in any orientation other than Head First Supine (HFS). Customers are instructed, until the updated software is install at their institution, the Recalling Firm recommends using only the HFS orientation when treating patients on the affected systems. It is estimated that a software updated to address the issue will be installed at all sites by mid to late January 2022. For questions, contact the Senior Director of Technical Support at 650-263-8888 or email support@reflexion.com
Initiated
2021-11-24
Root cause
Software design
Terminated
2024-07-08
Distribution
U.S. Nationwide distribution in the states of CA and TX
Recall number
Z-0470-2022
Recall status
Terminated
CDRH record ID
190799
FDA record created
2022-01-10
Recall event number
89212

Source facts and excerpts are reproduced for research. Dates retain their source meanings. “First observed” describes collection, not FDA publication or product launch.

Recall classification is supplied only when the recall number matches an enforcement record. Recall class and device class are different fields. Several recall records may belong to one recall event.

Useful context

Device classifications

FDA dataset:

Last successful check: Nov 22, 2026

Source classifications may change.

510(k) clearances

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset monthly.

Recall records

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset weekly.

Keep this research moving.

Follow ten competitors and ten product codes. Get matching changes in your dashboard and a weekly brief, for $49/month.

Start a 14-day free trial ↗