Skip to content

Public FDA record

Z-0574-03: Invacare Lynx and Panther Scooters, motorized 3-wheeled vehicles.

Recall record Z-0574-03 for Invacare Corp. View source facts, labeled dates, and the original FDA record.

FDA identifier
Z-0574-03
Company in FDA record
Invacare Corp
FDA classification date
Feb 25, 2003
First observed by MedTech Watch
Nov 16, 2026
Latest observed content change
Nov 20, 2026
Recall classification
Unknown — no matched enforcement classification

Reason stated in the source

A short circuit within the charger harness may cause heat damage to the units with potential for fire.

Source facts

Action
On 3/10/2003, the firm mailed recall letters to all affected dealer accounts. The dealers were asked to contact all customers who have purchased the scooters.
Initiated
2003-02-10
Root cause
Other
Terminated
2012-04-12
Distribution
The scooters were shipped to dealerships located nationwide, and to foreign distributors located in Barbados, Argentina, Isreal, and Bermuda.
Recall number
Z-0574-03
Recall status
Terminated
CDRH record ID
25927
FDA classified
2003-02-25
Recall event number
25495

Source facts and excerpts are reproduced for research. Dates retain their source meanings. “First observed” describes collection, not FDA publication or product launch.

Recall classification is supplied only when the recall number matches an enforcement record. Recall class and device class are different fields. Several recall records may belong to one recall event.

Useful context

Device classifications

FDA dataset:

Last successful check: Nov 22, 2026

Source classifications may change.

510(k) clearances

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset monthly.

Recall records

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset weekly.

Keep this research moving.

Follow ten competitors and ten product codes. Get matching changes in your dashboard and a weekly brief, for $49/month.

Start a 14-day free trial ↗