Open original FDA record ↗Recall record
- FDA identifier
- Z-0582-2019
- Company in FDA record
- Heartware, Inc.
- FDA record creation date
- Dec 7, 2018
- First observed by MedTech Watch
- Nov 16, 2026
- Latest observed content change
- Nov 16, 2026
- Recall classification
- Class II
Reason stated in the source
HVAD Battery Charger units manufactured with wrong inductors.
Source facts
- Action
- On November 2018 Medtronic sent the following letter to all their consignees: Dear Physician or Healthcare Professional: HeartWare, now a part of Medtronic, has been notified by an outside vendor that a quantity of HVAD battery charger units (see image above) may have been manufactured with an incorrect circuit component. This subset may exhibit one or more of the battery charging bays not fully charging the battery and/or battery charger indicators (LED) not lighting. The behaviors may occur in any individual bay, independent of the other charging bays. In analyzed units, up to 2 charging bays exhibited one of the above behaviors. In all cases, at least 2 of the remaining bays were able to continue to charge batteries as needed. We are not able to predict if, or when, one of the identified battery charger units may malfunction. The potential exists, however, that all circuits responsible for charging batteries and LED function may fail due to the incorrect component. In the population of potentially affected product, Medtronic has observed a malfunction rate of 16.7%. The number of potentially affected battery chargers remaining in distribution is estimated to be 2031 worldwide. These units were distributed between June 2017 and June 2018. Charging units outside of the serial numbers listed in Appendix A, all new manufactured battery chargers, and the individual batteries are not in scope of this advisory. Through November 02, 2018, Medtronic has received zero (0) reports of patient injuries associated with this issue. Patient Management Recommendations We realize that each patient requires unique clinical considerations. In consultation with Medtronics Independent Practitioner Quality Panel (IPQP), the following recommendations are provided: For patients with a HeartWare Battery Charging Unit in the identified list of Serial Numbers (refer to Appendix A): " Instruct patients to monitor the battery charging unit for any of the following beha
- Initiated
- 2018-11-19
- Root cause
- Other
- Terminated
- 2020-07-21
- Distribution
- Worldwide distribution - US nationwide distribution in the state of AL, AR, AZ, CA, CO, CT, DC, FL, GA, IA, IL, IN, KS, KY, LA, MA, MD, MI, MN, MO, MS, NC, NE, NJ, NY, OH, OR, PA, SC, TN, TX, UT, VA, WA, and WI. Countries of Australia, Austria, Belgium, Canada, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hong Kong, India, Italy, Latvia, Lebanon, Netherlands, Poland, Slovakia, South Africa, Spain, Sweden, Switzerland, Turkey, United Arab Emirates, and United Kingdom.
- Recall number
- Z-0582-2019
- Recall status
- Terminated
- CDRH record ID
- 169057
- FDA record created
- 2018-12-07
- Recall event number
- 81609