Z-0744-2025: TEMA Elbow - Axle Small REF 1590.15.010 TEMA Elbow - Axle Large REF 1590.15.020 TEMA Elbow System is a

Recall record Z-0744-2025 for Limacorporate S.p.A. View source facts, labeled dates, and the original FDA record.

FDA identifier
Z-0744-2025
Company in FDA record
Limacorporate S.p.A
FDA classification date
Dec 20, 2024
First observed by MedTech Watch
Nov 16, 2026
Latest observed content change
Nov 16, 2026
Recall classification
Class II

Reason stated in the source

Due to a potential difference in mechanical behavior between the implanted device and tool(s) used during revision surgery.

Source facts

Action
On 10/02/2024, the firm notified U.S. surgeons of the recall and the two U.S. distributors were informed via email on 10/11/2024. An updated/follow-up Recall Notification and Acknowledgement form is pending. The update/follow-up Recall Notification is informing surgeons and distributors that the firm has received a total of two similar complaints, regarding issues related to difficulty in disassembly of the axle component by using the screwdriver as per Surgical Technique. According to the internal investigation, the main concurring root causes of the problem seem to be the incomplete shot peening on the taper and the missing identification of a critical dimension (thread length). The Recall Notification informs surgeons to use other instruments available in the Operating Room to successfully complete the surgery or, in the worst case, several parts/the entire implant (both the humeral and the ulnar components) should be removed. Surgeons are also asked to Fill out, sign, and send the following Acknowledgement and Receipt Form via email as confirmation that You have read and acknowledged the content of this document. For questions or assistance, contact: Contact of the Importer: Kenneth Newman - Senior Regulatory Affairs Specialist (LimaCorporate now Enovis) /Recall Coordinator (Enovis) E-mail: Kenneth.Newman@enovis.com Or to the Manufacturer contact point: Federica Malvaso Post-Market Surveillance Lead (LimaCorporate now Enovis) E-mail: pms@enovis.com Distributors are instructed to: Check your stock to locate and quarantine the affected devices. Devices must be sent back to: Lima U.S.A., Inc. | 2001 NE Green Oaks Blvd. Ste.100 | Arlington, Texas 76006 | USA within 15 days together with a signed hard copy of the following Acknowledgement and Receipt Form.
Initiated
2024-10-02
Root cause
Process control
Distribution
U.S: FL and TX O.U.S.: N/A
Recall number
Z-0744-2025
Recall status
Open, Classified
CDRH record ID
211027
FDA classified
2024-12-20
Recall event number
95732

Source facts and excerpts are reproduced for research. Dates retain their source meanings. “First observed” describes collection, not FDA publication or product launch.

Recall classification is supplied only when the recall number matches an enforcement record. Recall class and device class are different fields. Several recall records may belong to one recall event.

Useful context

Device classifications

FDA dataset:

Last successful check: Nov 22, 2026

Source classifications may change.

510(k) clearances

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset monthly.

Recall records

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset weekly.

Keep this research moving.

Follow ten competitors and ten product codes. Get matching changes in your dashboard and a weekly brief, for $49/month.

Start a 14-day free trial ↗