Open original FDA record ↗Recall record
- FDA identifier
- Z-0768-2025
- Company in FDA record
- Jinan Bodor Cnc Machine Co Ltd
- FDA classification date
- Jan 18, 2025
- First observed by MedTech Watch
- Nov 16, 2026
- Latest observed content change
- Nov 16, 2026
- Recall classification
- Class II
Reason stated in the source
Non-compliant laser products
Source facts
- Action
- Bodor Laser will write to inform all dealers and purchaser that the [P or C] series product(s) you purchased from Bodor may require an update. Specifically, Bodor will take the following steps: 1. For correction of defective products related to 21 CFR 1040.10(f)(1) Protective Housing, Bodor will perform inspections and installations of vision-based collision detection function to ensure that when an operator enters the protective enclosure, the equipment automatically detects their presence and stops operating. 2. For correction of defective products related to 21 CFR 1040.10(f)(2) Safety Interlocks, Bodor will perform inspections and installations of safety interlocks on the side doors to ensure that the equipment automatically stops when the side doors are The inspection, installation and/or repair, and testing may be conducted at your location. Bodor will remedy the defect or bring the product into compliance at no charge. Bodor will contact you to arrange a mutually agreeable time for the update operations to take place.
- Initiated
- 2024-12-19
- Root cause
- Radiation Control for Health and Safety Act
- Distribution
- US Nationwide Distribution
- Recall number
- Z-0768-2025
- Recall status
- Open, Classified
- CDRH record ID
- 211822
- FDA classified
- 2025-01-18
- Recall event number
- 96035