Open original FDA record ↗Recall record
- FDA identifier
- Z-0781-2014
- Company in FDA record
- Ranir Corporation
- FDA classification date
- Jan 17, 2014
- First observed by MedTech Watch
- Nov 16, 2026
- Latest observed content change
- Nov 16, 2026
- Recall classification
- Class II
Reason stated in the source
Ranir, LLC is recalling all lots of Up & Up brand Kid's Power Toothbrush and TopCare brand Clifford Kids Power Toothbrush because the tufted disk may become detached from the power brush handle. If the tuft retention disk detaches from the handle, it is a potential choking hazard for children three years old and younger.
Source facts
- Action
- Ranir, LLC phoned their two direct accounts notifying them of this recall on December 12, 2013. On December 18, 2013, Ranir, LLC sent an URGENT: MEDICAL DEVICE RECALL notification letter was sent to their direct accounts. The notification stated the affected product, issue, and instructions for responding to the notification, including instructions for return of the affected product. Questions are directed to Paula Bojsen (616)698-8880.
- Initiated
- 2013-12-18
- Root cause
- Device Design
- Terminated
- 2015-08-20
- Distribution
- Distributed in MN and IL.
- Recall number
- Z-0781-2014
- Recall status
- Terminated
- CDRH record ID
- 124741
- FDA classified
- 2014-01-17
- Recall event number
- 67123