Z-0781-2024: Sedecal X Optima URS digital mobile diagnostic x-ray system. A a stationary x-ray unit with a universa

Recall record Z-0781-2024 for SEDECAL SA. View source facts, labeled dates, and the original FDA record.

FDA identifier
Z-0781-2024
Company in FDA record
SEDECAL SA
FDA classification date
Jan 23, 2024
First observed by MedTech Watch
Nov 16, 2026
Latest observed content change
Nov 16, 2026
Recall classification
Class II

Reason stated in the source

Some parts have fallen off the equipment resulting in a safety risk to patients and/or users.

Source facts

Action
On 12/13/2023, the recalling firm emailed the recall letter dated 12/11/2023 to their distributor customers along with attachments for service and maintenance of the units. The letter explained a description of the issue and that the installed devices should be inspected to ensure they are being used in a safe mode (the unit has been properly maintained and does not show any signs of the screws loosening) and to fix any potential issues. This inspection will also be included in all scheduled maintenance tasks to be performed in the future. The letter is to be distributed to all staff involved. The letter included 3 attachments. Annex 1 contains further information regarding the issue. Annex 2 is the acknowledgement of receipt of the notification and understanding of the described problem and its importance. Annex 3 is confirmation that the mandatory field checks or upgrade of the affected unit is complete. The firm reported distributors will provide the information to the medical facility either by using the recalling firm's letter or creating a new letter.
Initiated
2023-12-13
Root cause
Equipment maintenance
Distribution
Distribution was made to AL, FL, and NC. There was no military/government distribution.
Recall number
Z-0781-2024
Recall status
Open, Classified
CDRH record ID
204969
FDA classified
2024-01-23
Recall event number
93614

Source facts and excerpts are reproduced for research. Dates retain their source meanings. “First observed” describes collection, not FDA publication or product launch.

Recall classification is supplied only when the recall number matches an enforcement record. Recall class and device class are different fields. Several recall records may belong to one recall event.

Useful context

Device classifications

FDA dataset:

Last successful check: Nov 22, 2026

Source classifications may change.

510(k) clearances

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset monthly.

Recall records

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset weekly.

Keep this research moving.

Follow ten competitors and ten product codes. Get matching changes in your dashboard and a weekly brief, for $49/month.

Start a 14-day free trial ↗