Z-0946-2021: Medtronic HVAD Pump Implant Kits, labeled as: a. PUMP 1103, b. PUMP 1104, c. PUMP 1104JP, d. PUMP 1

Recall record Z-0946-2021 for Heartware, Inc.. View source facts, labeled dates, and the original FDA record.

FDA identifier
Z-0946-2021
Company in FDA record
Heartware, Inc.
FDA classification date
Feb 4, 2021
First observed by MedTech Watch
Nov 16, 2026
Latest observed content change
Nov 16, 2026
Recall classification
Class I

Reason stated in the source

Pumps manufactured with impellers from a subset of lots from a single supplier are failing to initially start, restart, or experiencing a delay in restart within the maximum number of restart attempts at a rate substantially higher than pump in the overall population.

Source facts

Action
On 11/19/2020, notifications initiated to inform about recall. Additional notifications sent on 5/18/2022 (https://www.medtronic.com/content/dam/medtronic-com/global/HCP/Documents/hvad-urgent-medical-device-notice-update-june-2022.pdf), 10/13/2022 and May 08, 2024. On 8/20/2025, communications initiated to inform about algorithm C controller that will attempt to pump restart using algorithm A, and if needed algorithm B. It will mitigate controller resetting. Blue line highlights on algorithm C controller exterior differentiates it from previous versions. Healthcare providers asked to speak with patients. Issue does not cause a running pump to stop; rather, a failure to restart may follow a pump stop event. A controller AC adapter should be attached to any controller being used to restart a stopped pump, which will provide consistent power for restart attempts. If unavailable, connect two fully or partially charged batteries to the controller as soon as possible during any pump restart attempt. Reinforce patient manual and instructions for use: -Do NOT disconnect the driveline from controller. - ALWAYS ensure two power sources are connected to controller. - NEVER disconnect both power sources (batteries and AC or DC adapter) from controller at the same time; one external power source should remain connected to controller at all times. - Do NOT exchange controller unless explicitly directed by a high priority alarm condition or a VAD team member. - Reinforce the proper response to a Controller Fault alarm and Electrical Fault alarm. These are medium priority alarms unrelated to an immediate pump stop. These alarms will result in the word Call in the controller display, notifying the patient to call their clinician. - Reinforce making good connections of power sources and the data cable in the controller ports. Complete and return response form via email to rs.cfqfca@medtronic.com
Initiated
2020-11-19
Root cause
Under Investigation by firm
Distribution
Worldwide - US Nationwide
Recall number
Z-0946-2021
Recall status
Open, Classified
CDRH record ID
184844
FDA classified
2021-02-04
Recall event number
86924

Source facts and excerpts are reproduced for research. Dates retain their source meanings. “First observed” describes collection, not FDA publication or product launch.

Recall classification is supplied only when the recall number matches an enforcement record. Recall class and device class are different fields. Several recall records may belong to one recall event.

Useful context

Device classifications

FDA dataset:

Last successful check: Nov 22, 2026

Source classifications may change.

510(k) clearances

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset monthly.

Recall records

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset weekly.

Keep this research moving.

Follow ten competitors and ten product codes. Get matching changes in your dashboard and a weekly brief, for $49/month.

Start a 14-day free trial ↗