Z-1219-2018: (1) Sigma HP Cemented Trochlea Size 1 Narrow Left, Catalog Number: 102403100, GTIN: 10603295001614; (2) S

Recall record Z-1219-2018 for DePuy Orthopaedics, Inc.. View source facts, labeled dates, and the original FDA record.

FDA identifier
Z-1219-2018
Company in FDA record
DePuy Orthopaedics, Inc.
FDA classification date
Mar 20, 2018
First observed by MedTech Watch
Nov 16, 2026
Latest observed content change
Nov 16, 2026
Recall classification
Class II

Reason stated in the source

The SIGMA HP PFJ Cemented Trochlear Implants, a standalone component of the partial knee system is being recalled based on elevated revision rates observed as part of the company s post market surveillance process.

Source facts

Action
Notifications were sent to the firm's consignees with the following instructions. Immediately Inspect Inventory: DISTRIBUTORS & SALES OFFICES: Inspect all inventory to identify any affected devices. 2. Return Affected U.S. Distributor/Sales Office Inventory: If any affected devices are found in a U.S. Distributors/Sales Offices inventory, return to: DePuy Synthes Joint Reconstruction 3. To Expedite the Return Process: Be sure to reference H17-19 on all return paperwork and/or online return forms and on the outside of the box when returning recalled devices. 4. Upon receipt of the affected devices, a credit will be issued using the normal returns process. 5. Identify Consignment Hospitals: Within 5-business days, complete the Distributor / Sales Office Response Card: 5.1. Provide the Medical Facility contact information and indicate the US Distributor/Sales Office has returned all affected devices. MEDICAL PROFESSIONALS: Steps to Take: " Cease using the affected components. " Return Affected Implants: Complete the reconciliation form and return to the sales consultant or fax to 574-371-4939 within five (5) days of this notice. Additional Notifications: o Notify surgeon users at your facility by providing them with a copy of this notice to ensure surgeon users are aware of this device recall. Forward this notice to others in your facility that need to be informed. o If any affected product has been forwarded to another facility, contact that facility immediately to communicate this field action with the facility/facilities. For further questions, please call (574) 372-7136.
Initiated
2017-12-21
Root cause
Under Investigation by firm
Terminated
2020-04-01
Distribution
Worldwide Distribution - USA (nationwide) Distribution including Puerto Rico and to the states of : AK, AL, AR, AZ, CA, CO, CT, DE, FL, GA, HI, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WI, WV, WY, and the District of Columbia., and to the countries of : Australia, Austria, Belgium, Canada, Croatia, Denmark, Finland, France, Germany, India, Ireland, Italy, Korea, Luxembourg, Malaysia, Netherlands, Portugal, Singapore, Slovakia. Slovenia, South Africa, Spain, Sweden, Switzerland, Thailand, Turkey, and United Kingdom.
Recall number
Z-1219-2018
Recall status
Terminated
CDRH record ID
162430
FDA classified
2018-03-20
Recall event number
79475

Source facts and excerpts are reproduced for research. Dates retain their source meanings. “First observed” describes collection, not FDA publication or product launch.

Recall classification is supplied only when the recall number matches an enforcement record. Recall class and device class are different fields. Several recall records may belong to one recall event.

Useful context

Device classifications

FDA dataset:

Last successful check: Nov 22, 2026

Source classifications may change.

510(k) clearances

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset monthly.

Recall records

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset weekly.

Keep this research moving.

Follow ten competitors and ten product codes. Get matching changes in your dashboard and a weekly brief, for $49/month.

Start a 14-day free trial ↗