Skip to content

Public FDA record

Z-1235-2016: KAMRA Inlay, ACI 7000 Corneal Inlay, Part No. 76195-01 and 76195-10 (OUS) Labeling: The KAMRA inlay is i

Recall record Z-1235-2016 for AcuFocus, Inc.. View source facts, labeled dates, and the original FDA record.

FDA identifier
Z-1235-2016
Company in FDA record
AcuFocus, Inc.
FDA record creation date
Mar 24, 2016
First observed by MedTech Watch
Nov 16, 2026
Latest observed content change
Nov 16, 2026
Recall classification
Class II

Reason stated in the source

AcuFocus is recalling KAMRA ACI 7000 Corneal Inlays due to concerns with the labeled shelf life.

Source facts

Action
The firm, AcuFocus, sent an "URGENT FIELD SAFETY NOTICE" letter dated 2/11/16 to all their customers to inform them that AcuFocus is recalling 2 lots of KAMRA ACI 7000 Corneal Inlays due to concerns with the labeled shelf life. The described the product, problem and the actions to be taken. Customers are instructed to report any abnormal appearance of the implanted KAMRA inlay to AcuFocus, inc; stop using and remove from your inventory all affected lots; complete and return the attached Customer Recall Response Form via email: customerservice@acufocus.com, Fax: +1 (949) 585-9545 Attn: Recall Coordinator, or mail to: AcuFocus Inc., Attn: Recall Coordinator, 32 Discovery, Suite 200, Irvine CA 92618, within 3 business days even if you have no inventory affected by this recall; and provide the attached Customer Field Safety Notice and Customer Recall Response Form to your customers who have or may have received product from the affected two lots. Customers with product complaint events are instructed to report regarding KAMRA inlays involved in this recall event, and to inform AcuFocus, Inc. by calling +1 (949) 585-9511 ext 608. Customers with any questions related to the return process, are instructed to contact an AcuFocus Customer Service Representative at +1 (949) 585-9511 ext 608.
Initiated
2016-02-11
Root cause
Under Investigation by firm
Terminated
2016-05-04
Distribution
International distribution in countries of: Canada, Germany, Saudi Arabia, Turkey, and United Kingdom.
Recall number
Z-1235-2016
Recall status
Terminated
CDRH record ID
143915
FDA record created
2016-03-24
Recall event number
73343

Source facts and excerpts are reproduced for research. Dates retain their source meanings. “First observed” describes collection, not FDA publication or product launch.

Recall classification is supplied only when the recall number matches an enforcement record. Recall class and device class are different fields. Several recall records may belong to one recall event.

Useful context

Device classifications

FDA dataset:

Last successful check: Nov 22, 2026

Source classifications may change.

510(k) clearances

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset monthly.

Recall records

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset weekly.

Keep this research moving.

Follow ten competitors and ten product codes. Get matching changes in your dashboard and a weekly brief, for $49/month.

Start a 14-day free trial ↗