Open original FDA record ↗Recall record
- FDA identifier
- Z-1724-2011
- Company in FDA record
- Brushpoint Innovations, Inc.
- FDA classification date
- Mar 18, 2011
- First observed by MedTech Watch
- Nov 16, 2026
- Latest observed content change
- Nov 17, 2026
- Recall classification
- Unknown — no matched enforcement classification
Reason stated in the source
The power toothbrush may make a loud noise and the battery cap becomes separated from the main body of the toothbrush. The battery cap can become a projectile that could cause potential injury if it comes in contact with the body.
Source facts
- Action
- The firm, BrushPoint Innovations, sent a email dated January 7, 2011 notifying their customers of the recall. The email described the product, problem and actions to be taken. The customers were instructed to pull and quarantine the toothbrushes due to potential product quality concerns, and hold their stocks until January 14, 2011, call in the number of toothbrushes quarantined, and then return them to the Walgreen distribution centers. A stop sale was placed on the affected item numbers in their cash register scanners. If you have any questions, call 905-833-5122 or 905-944-1000.
- Initiated
- 2011-01-14
- Root cause
- Device Design
- Terminated
- 2012-12-16
- Distribution
- Nationwide distribution.
- Recall number
- Z-1724-2011
- Recall status
- Terminated
- CDRH record ID
- 96951
- FDA classified
- 2011-03-18
- Recall event number
- 57674