Z-1755-2020: TCM4 Base unit, Ref 391-880, UDI:(01)05700693918808, used with the monitor modules TCM4 (902-778), TCM40

Recall record Z-1755-2020 for Radiometer Medical ApS. View source facts, labeled dates, and the original FDA record.

FDA identifier
Z-1755-2020
Company in FDA record
Radiometer Medical ApS
FDA record creation date
Apr 22, 2020
First observed by MedTech Watch
Nov 16, 2026
Latest observed content change
Nov 16, 2026
Recall classification
Class II

Reason stated in the source

Reports have been received about the transcutaneous monitoring system display flickering or monitor becoming non responsive and beeping. This may result in delayed patient monitoring as well as potentially compromise the product performance.

Source facts

Action
On February 20, 2020, a "Urgent: Medical device Recall" letter was sent to affected consignees via E-Mail and FedEx 2nd day delivery. In addition to informing consignees about the recall, the customer notification asked customers to take the following actions: 1. Cease using the affected TCM4 Base unit and put it on quarantine. 2. Complete the Recall Response Form (last page of this letter) and submit to your Radiometer representative. 3. Your Radiometer representative will exchange the computer hardware of your TCM4 Base unit as soon as possible when we receive replacement components. 4. If you are not the end-user of the affected product, please ensure that this letter is distributed to the final end-users. 5. If you have any questions, please contact us at 1-800-736-0600 option 1, Monday Friday 9am EST to 7pm EST
Initiated
2020-02-20
Root cause
Under Investigation by firm
Terminated
2022-06-24
Distribution
Worldwide distribution - US Nationwide distribution including the states of FL, KS, NY, ND, IN, TX, CA , VA, MA, MN, WI, IN, CT, WA and the countries of China, India, Japan, south Korea.
Recall number
Z-1755-2020
Recall status
Terminated
CDRH record ID
180816
FDA record created
2020-04-22
Recall event number
85257

Source facts and excerpts are reproduced for research. Dates retain their source meanings. “First observed” describes collection, not FDA publication or product launch.

Recall classification is supplied only when the recall number matches an enforcement record. Recall class and device class are different fields. Several recall records may belong to one recall event.

Useful context

Device classifications

FDA dataset:

Last successful check: Nov 22, 2026

Source classifications may change.

510(k) clearances

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset monthly.

Recall records

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset weekly.