Z-1838-2021: RayStation (Treatment Planning System) Model Number RayStation is 6.0.0.24 , 6.1.1.2 , 6.2.0.7 , 6.3.

Recall record Z-1838-2021 for RAYSEARCH LABORATORIES AB. View source facts, labeled dates, and the original FDA record.

FDA identifier
Z-1838-2021
Company in FDA record
RAYSEARCH LABORATORIES AB
FDA record creation date
Jun 9, 2021
First observed by MedTech Watch
Nov 16, 2026
Latest observed content change
Nov 16, 2026
Recall classification
Class II

Reason stated in the source

Evaluation of a clinical goal for the voxelwise worst dose distributions may be misleading after editing the clinical goal. It also describes an issue with contouring when the spacing between slices is d 1 mm, present in RayStation/RayPlan versions from 6 up to 10A.

Source facts

Action
On May 6, 2021, Raysearch issued an Urgent Medical Device Correction notice to customers via letter notifying them an issue was found with the voxelwise worst clinical goals in the Robust evaluation module for specified software versions of RayStation. Evaluation of a clinical goal for the voxelwise worst dose distributions may be misleading after editing the clinical goal. Actions to be taken by the user Voxelwise worst clinical goal in Robust evaluation - The user is advised to be careful when editing clinical goals in the Robust evaluation module and when evaluating the clinical goals for the voxelwise worst distributions. If a clinical goal needs to be edited, make sure to toggle between the Scenario view and Voxelwise min and max views to trigger an update. Contouring issue - The user is advised to always examine ROI geometries in the transversal view and in the reconstructed sagittal, coronal and 3D views to verify that they have the desired size and shape. - To avoid displaying a mix of manually drawn and reconstructed contours in the same 2D view, the user can explicitly convert the ROI geometry to voxel- or mesh representation by using the keep component tool or the deformation tool. This way all rendered contours will be reconstructed and also be identical to what will be exported. All - Educate planning staff and all users about these issues and the workarounds. - Inspect your product and identify all installed units with the above software version number(s). - Confirm you have read and understood this notice by replying to the notification email. Solution The voxelwise worst issue will be resolved in the next version of RayStation, scheduled for market release in May 2021 (subject to market clearance in some markets). The contouring issue was resolved in RayStation 10B. If customers wish to continue using versions of RayStation affected by this notice, all users must maintain awareness of this notice. Alternatively, customers ca
Initiated
2021-04-21
Root cause
Under Investigation by firm
Terminated
2023-07-27
Distribution
Worldwide distribution - US Nationwide distribution in the states of AK, AL, AZ, CA, CT, DC, DE, FL, GA, HI, ID, IL, LA, MA, MD, ME, MI, MO, MS, MT, NC, NJ, NM, NY, OH, OK, OR, PA, RI, SC, TN, TX, UT, VA, VT, WA, WI and the countries of Algeria, Australia, Austria, Bahrain, Belgium, Canada, Colombia, Czech Republic, Denmark, Egypt, Estonia, France, French Polynesia, Germany, Hong Kong, China, India, Indonesia, Iran, Israel, Italy, Japan, Korea, Malaysia, Morocco, Netherlands, New Zealand, Norway, Poland, Qatar, Singapore, Slovenia, Spain, Sweden, Switzerland, Taiwan, Thailand, Turkey, UAE, UK,
Recall number
Z-1838-2021
Recall status
Terminated
CDRH record ID
187596
FDA record created
2021-06-09
Recall event number
87977

Source facts and excerpts are reproduced for research. Dates retain their source meanings. “First observed” describes collection, not FDA publication or product launch.

Recall classification is supplied only when the recall number matches an enforcement record. Recall class and device class are different fields. Several recall records may belong to one recall event.

Useful context

Device classifications

FDA dataset:

Last successful check: Nov 22, 2026

Source classifications may change.

510(k) clearances

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset monthly.

Recall records

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset weekly.

Keep this research moving.

Follow ten competitors and ten product codes. Get matching changes in your dashboard and a weekly brief, for $49/month.

Start a 14-day free trial ↗