Skip to content

Public FDA record

Z-1883-2024: Stryker Blueprint Software, Catalog #BPUE001.

Recall record Z-1883-2024 for Tornier S.A.S.. View source facts, labeled dates, and the original FDA record.

FDA identifier
Z-1883-2024
Company in FDA record
Tornier S.A.S.
FDA classification date
May 22, 2024
First observed by MedTech Watch
Nov 16, 2026
Latest observed content change
Nov 16, 2026
Recall classification
Class II

Reason stated in the source

The software bug allows for case planning with anatomic glenoid Perform / Perform Augmented implants and anatomic humeral Tornier Flex implant configurations that are incompatible and do not have regulatory approval.

Source facts

Action
The firm issued letters via email on 4/16/2024. The email provided the issue and risks and said that for additional information regarding risks, exact incompatible configuration details, and steps for you to take, please refer to the attached document. The email listed a requested action, which was to review the case information provided on the business acknowledgment form, confirm the final implants used in this surgery, and complete and sign the response form on Page 4 at their earliest convenience. The attached Urgent Medical Device Recall letter was dated 16-April-2024 and provided the product affected, product description, product issue, potential risks, and actions needed by customers and distributors. Those actions included: 1. Review the case information provided on the business acknowledgment form and confirm the final implants used in this surgery. Return the enclosed business reply form by email to confirm receipt and understanding of this notice. 2. A software patch, Version 4.1.1, is currently in development and is scheduled for release by April 16, 2024. This software patch will resolve this issue and prevent the selection of these incompatible implants. 3. Please ensure that all potential users of these products within your facility are made aware of this notification and instruct all potential users to reference this notice prior to use. 4. Maintain awareness of this communication internally until all required actions have been completed within your facility. 5. Please inform us of any adverse event and/or report them to the Health/Competent Authorities in accordance with current regulations. For questions or concerns, please contact memphis.fieldaction@stryker.com.
Initiated
2024-04-16
Root cause
Software change control
Distribution
US Nationwide distribution in the states of FL, KY, NJ, and WI.
Recall number
Z-1883-2024
Recall status
Open, Classified
CDRH record ID
207225
FDA classified
2024-05-22
Recall event number
94444

Source facts and excerpts are reproduced for research. Dates retain their source meanings. “First observed” describes collection, not FDA publication or product launch.

Recall classification is supplied only when the recall number matches an enforcement record. Recall class and device class are different fields. Several recall records may belong to one recall event.

Useful context

Device classifications

FDA dataset:

Last successful check: Nov 22, 2026

Source classifications may change.

510(k) clearances

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset monthly.

Recall records

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset weekly.

Keep this research moving.

Follow ten competitors and ten product codes. Get matching changes in your dashboard and a weekly brief, for $49/month.

Start a 14-day free trial ↗