Open original FDA record ↗Recall record
- FDA identifier
- Z-2262-2020
- Company in FDA record
- Ventana Medical Systems Inc
- FDA record creation date
- Jun 5, 2020
- First observed by MedTech Watch
- Nov 16, 2026
- Latest observed content change
- Nov 16, 2026
- Recall classification
- Class II
Reason stated in the source
The firm became aware of a cleaning solution leaking issue from the middle staining module of the Ventana HE 600 instrument, used for histologic section samples in anatomic pathology laboratory settings, which caused fluid to travel down to the electrical wiring connector of the Coverslipper solvent shield circuit board. This can cause an electrical short and result in burned components.
Source facts
- Action
- All US consignee accounts who are utilizing the VENTANA HE 600 system were to receive a copy of the Urgent Medical Device Correction (UMDC) notification, VENTANA HE 600 Instrument - Fluid Leak and Risk of Burned Components, via UPS Ground on 10/16/19. It notified user that Roche Tissue Diagnostics received notification of an issue on the VENTANA HE 600 instrument. A leak from the middle staining module caused fluid to travel down to the electrical wiring connector of the Coverslipper solvent shield circuit board. This caused an electrical short and resulted in burned components. It stated clinical significance that there is a remote possibility that use of the VENTANA HE 600 system would result in adverse health consequences. It advised users that Roche Service Representatives will remove the cable that conducts electricity to the Coverslipper Module LED PCBA, proactively replace the Stainer Exchange Valves, and proactively replace the 65 micron filters in the Cleaning Solution fluidics line. Site visits will be scheduled as appropriate. Customers can continue using the instrument as normal. However, if droplets are observed on the instrument Coverslip Module during normal operation: stop instrument operation, unplug the instrument, and contact your Roche Service Representative immediately. Actions Required: " If customers observe droplets on the instrument Coverslip Module during normal operation: stop instrument operation, unplug the instrument, and contact your Roche Service Representative immediately. " Complete attached fax form and fax or email it according to the instructions on the form. " File the Urgent Medical Device Correction (UMDC) for future reference. Customers can contact the Roche Support Network Customer Support Center, 24 hours a day, seven days a week at 1-800-227-2155 if they have questions about the information contained in the UMDC. Adverse events or quality problems experienced with the use of this product may also be reported to
- Initiated
- 2019-10-04
- Root cause
- Under Investigation by firm
- Distribution
- Worldwide distribution - US Nationwide distribution including in the states of AL, AZ, CA, CO, CT, FL, GA, HI, IA, IL, IN, KS, KY, MD, MI, MA, MN, MO, MS, MT, NC, NE, NJ, NY, OH, OK, PA, PR, SC, SD, TN, TX, UT, VA, WA, WI and the countries of Australia, Austria, Belgium, Brazil, Canada, Chile, China, Columbia, Costa Rica, Croatia, Denmark, Ecuador, El Salvador, Finland, France, Germany, Hong Kong, Ireland, Italy, Japan, Kuwait, Lebanon, Malaysia, Norway, Peru, Poland, Saudi Arabia, Slovakia, Slovenia, South Korea, Spain, Sweden, Switzerland, Taiwan, Thailand, United Arab Emirates, United Kingdom, Vietnam.
- Recall number
- Z-2262-2020
- Recall status
- Completed
- CDRH record ID
- 181168
- FDA record created
- 2020-06-05
- Recall event number
- 85526