Z-2320-2019: ABL90 FLEX Analyzer REF 393090 UDI:05700693930909

Recall record Z-2320-2019 for Radiometer America Inc. View source facts, labeled dates, and the original FDA record.

FDA identifier
Z-2320-2019
Company in FDA record
Radiometer America Inc
FDA classification date
Aug 22, 2019
First observed by MedTech Watch
Nov 16, 2026
Latest observed content change
Nov 16, 2026
Recall classification
Class II

Reason stated in the source

Software Security; The action is being initiated because of software security vulnerabilities with the firm's analyzer operating system, which may cause the device to shutdown or reboot resulting in delayed medical treatment.

Source facts

Action
On (date), the firm will email a "Urgent Field Safety Notice" to all customers and will follow-up by mailing a copy of the "Urgent Field Safety Notice" to all customers via Federal Express with tracking and proof of delivery. The Urgent Field Safety Notice ask customers to do the following: 1. Check which version of the operating system (OS) is currently installed on your analyzer: o Logon to the analyzer o Touch Menu, Utilities, Temporary shutdown, and then Confirm o During the shutdown process the analyzer displays the version of OS installed " If the OS version is one of the following your analyzer is affected by the vulnerability: RXPE - UIM2743 v1.3.xxxxxx or RXPE-UIM910v1.3.xxxxxx 2. If your analyzer is found to be affected by the vulnerability the following options must be applied: Short term: If your analyzer is connected to a network and your IT department assesses that the Hospital Firewall and Network settings prevent a remote attacker from connecting to the analyzer to exploit the vulnerability, you may decide to keep the analyzer connected. Otherwise, we recommend disconnecting it until one of the long term countermeasures below has been implemented. Long term: Countermeasure 1: Contact your Radiometer representative to have the RXPE Security patch update installed on your analyzer. (Note: Microsoft does not support Windows XP anymore. However, Microsoft has extraordinarily released a patch for this particular vulnerability.) or Countermeasure 2: Contact your Radiometer representative to receive a quote for an upgrade to latest OS (Windows 7 embedded) from Radiometer, which is supported by Microsoft. 3.Please complete the Recall Response Form (last page of the customer advisory letter) and return it to your Radiometer representative. 4.Please Note: If you are not the end-user of the affected product, please ensure that this letter is distributed to the final end-users. If you have questions, please contact Radiometer
Initiated
2019-07-10
Root cause
Software design
Terminated
2022-06-13
Distribution
US: AB, AL, AR, BC, CA, CO, CT, FL, GA, IA, ID, IL, IN, KY, LA, MA, MD, ME, MI, MN, MO, MS, NC, NE, NH, NJ, NY, OH, OK, OR, PA, SC, TX, VA, VT, WA, WI, WV OUS: Canada, Netherland, China, Czech Republic, Denmark, Germany, Spain, France, Hugary, , indiat Japan, South Korea, United Kingdom, Australia, Poland, South Africa, Singapore, Switzerland, Turkey, Norway, Austria, Italy, Sweden, Finland, Brazil, and Mexico
Recall number
Z-2320-2019
Recall status
Terminated
CDRH record ID
174676
FDA classified
2019-08-22
Recall event number
83312

Source facts and excerpts are reproduced for research. Dates retain their source meanings. “First observed” describes collection, not FDA publication or product launch.

Recall classification is supplied only when the recall number matches an enforcement record. Recall class and device class are different fields. Several recall records may belong to one recall event.

Useful context

Device classifications

FDA dataset:

Last successful check: Nov 22, 2026

Source classifications may change.

510(k) clearances

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset monthly.

Recall records

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset weekly.

Keep this research moving.

Follow ten competitors and ten product codes. Get matching changes in your dashboard and a weekly brief, for $49/month.

Start a 14-day free trial ↗