Z-2388-2016: EtCO2 Module -Part Number: 02.01.210699 Monitors: iM80, iM50, M50, iM70, iM60, iM8, iM8A, iM8B Patient Mo

Recall record Z-2388-2016 for Edan Diagnostics. View source facts, labeled dates, and the original FDA record.

FDA identifier
Z-2388-2016
Company in FDA record
Edan Diagnostics
FDA record creation date
Oct 11, 2018
First observed by MedTech Watch
Nov 16, 2026
Latest observed content change
Nov 16, 2026
Recall classification
Class II

Reason stated in the source

Incorrect CO2 readings with some patient monitors.

Source facts

Action
The firm, EDAN, sent an "URGENT-MEDICAL DEVICE CORRECTION" letter dated 6/23/2016 via email to its customers on 06/23/16. The letter described the product, problem and actions to be taken. Customers were provided two possible solutions. 1. Re-calibrate the affected monitors: a. The customer needs to source the Calibration Gas and other tools locally, EDAN will provide the Specifications of the Calibration Gas; b. EDAN will provide Calibration Instructions to the customer; c. The customer need to calibrate the monitors by themselves and send the Calibration Record back to EDAN. 2. Replace the EtCO2 modules on the affected monitors: a. EDAN will provide new, correctly calibrated, EtCO2 modules with replacement instructions free of charge; b. The customer shall replace the modules by themselves and send the Replacement Record back to EDAN; c. The customer shall send the faulty EtCO2 modules back to EDAN. For customers who received affected EtCO2 modules as spare parts: 1. The customer can return the affected modules back to EDAN and ask for a refund or credit, or have these modules replaced with new ones. 2. If any of the affected module has been used on a monitor, the customer should replace the module used with new one. 3. The customer shall send the affected EtCO2 modules back to EDAN. Any questions contact EDAN service engineer who responsible for your country/region or at phone numbers listed below: EDAN Instruments, Inc. Monday to Friday 09:00-17:00 (UTC +08:00) Tel: +86-755-26812296 EDAN Instruments GmbH Monday to Friday 09:00-17:00 (UTC +01:00) Tel: +49 (0) 6103 202 0781 EDAN Diagnostics, Inc. Monday to Friday 09:00-17:00 (UTC -08:00) Tel: +1 858 750 3066
Initiated
2016-06-23
Root cause
Nonconforming Material/Component
Terminated
2016-11-16
Distribution
Worldwide Distribution-U.S (nationwide) distribution to the following states; FL, KY, CA; and countries of: Argentina, China, Colombia, , Ethiopia, France, Germany, Guatemala, India, Italy, Lao People's Democratic Republic, Lithuania, Malaysia, Macedonia, Nepal, New Caledonia, Nicaragua, Pakistan, Poland, Portugal, Russia, Saudi Arabia, South Africa, Sudan, Senegal, Sri Lanka, Thailand, Turkey, United Kingdom, and Uruguay.
Recall number
Z-2388-2016
Recall status
Terminated
CDRH record ID
148073
FDA record created
2018-10-11
Recall event number
74632

Source facts and excerpts are reproduced for research. Dates retain their source meanings. “First observed” describes collection, not FDA publication or product launch.

Recall classification is supplied only when the recall number matches an enforcement record. Recall class and device class are different fields. Several recall records may belong to one recall event.

Useful context

Device classifications

FDA dataset:

Last successful check: Nov 22, 2026

Source classifications may change.

510(k) clearances

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset monthly.

Recall records

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset weekly.

Keep this research moving.

Follow ten competitors and ten product codes. Get matching changes in your dashboard and a weekly brief, for $49/month.

Start a 14-day free trial ↗