Z-2519-2025: Brand Name: 900-00218 Sterile Cover 10-Pack Shipper Box Assembly Product Name: 900-00218 Sterile Cover 10

Recall record Z-2519-2025 for Lumicell, Inc.. View source facts, labeled dates, and the original FDA record.

FDA identifier
Z-2519-2025
Company in FDA record
Lumicell, Inc.
FDA classification date
Sep 4, 2025
First observed by MedTech Watch
Nov 16, 2026
Latest observed content change
Nov 16, 2026
Recall classification
Class II

Reason stated in the source

The potential of the elastic bands included in the kit detaching or fracturing during surgical procedures. As a result, these failures may pose a risk of retained foreign bodies in the surgical cavity and potentially leading to surgical site infections.

Source facts

Action
On July 31, 2025, URGENT: MEDICAL DECICE RECALL letters were sent to customers. Actions to be Taken by Customer: " Lumicell recommends that users dispose of the elastic bands and refrain from using them during the procedure. The Lumicell DVS may be used without elastic bands. " The elimination of elastic bands does not impact system performance. However, in the absence of elastic bands, there is a possibility that the secondary Sterile Probe Cover may shift during use. If this occurs, the Sterile Probe Cover may be repositioned, and Lumicell DVS use may continue. " If the included elastic bands are used, follow the Lumicell Direct Visualization System (DVS) Instructions for Use to ensure the bands are counted before and after the procedure to confirm the elastic bands are accounted for. " Please forward and post this notice for awareness to those who use it. If device was distributed or sold, please forward this notice to those accounts. " Adverse reactions or quality problems experienced with the use of this product may be reported to the FDA's MedWatch Adverse Event Reporting program either online, by regular mail or by fax. Please acknowledge receipt of this letter by completing the included response card. Next Actions: Lumicell is investigating the root cause of the issue and is working on a long-term solution. Lumicell will contact you in the future regarding updates. If you have any questions or need further assistance, please do not hesitate to reach out to our customer support team at 1-833-4-LUM-DVS (Monday through Friday, 9AM - 5PM Eastern Time) or email support@lumicell.com.
Initiated
2025-07-31
Root cause
Under Investigation by firm
Distribution
US Nationwide distribution in the states of CA, FL, MA, NC, TX.
Recall number
Z-2519-2025
Recall status
Open, Classified
CDRH record ID
215205
FDA classified
2025-09-04
Recall event number
97316

Source facts and excerpts are reproduced for research. Dates retain their source meanings. “First observed” describes collection, not FDA publication or product launch.

Recall classification is supplied only when the recall number matches an enforcement record. Recall class and device class are different fields. Several recall records may belong to one recall event.

Useful context

Device classifications

FDA dataset:

Last successful check: Nov 22, 2026

Source classifications may change.

510(k) clearances

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset monthly.

Recall records

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset weekly.

Keep this research moving.

Follow ten competitors and ten product codes. Get matching changes in your dashboard and a weekly brief, for $49/month.

Start a 14-day free trial ↗