Z-2777-2017: GE Inspection Technologies Blade|line Industrial Cabinet X-ray system

Recall record Z-2777-2017 for GE Inspection Technologies, LP. View source facts, labeled dates, and the original FDA record.

FDA identifier
Z-2777-2017
Company in FDA record
GE Inspection Technologies, LP
FDA record creation date
Aug 1, 2017
First observed by MedTech Watch
Nov 16, 2026
Latest observed content change
Nov 16, 2026
Recall classification
Class II

Reason stated in the source

GE Inspection Technologies, LP determined that the Blade|line cabinet x-ray system fails to comply with the cabinet x-ray performance standards emission limit of 0.5 milliRoentgen in one hour (21 CFR 1020.40(c)(1)(i)) underneath the bottom center of the system. The crawl space affected by the excess emission is approximately 22 inches high, normally covered by decorative panels, and is not intended to be accessed.

Source facts

Action
GE Inspection Technologies will bring the defect into compliance: 1. Four panels of sheet metal/lead/sheet metal construction (6 mm lead thickness) will be permanently mounted using an industrial epoxy to the inside floor of the cabinet to prevent emissions from exceeding the limit in the performance standard. A radiation emission measurement will be made following the repairs of each system to assure the issue was corrected. 2. GE will notify affected customers within 5 days of GEs receipt of this approval letter. 3. The notification will recommend that customers allow GE to visit the site and install the new shielding within 120 days following GEs receipt of this letter. 4.The text of the notification to customers will include the required statement that confirms that GE will, without charge, bring the affected cabinet x-ray systems into compliance with the performance standard. For further questions, please call (717) 447-1278.
Initiated
2017-06-28
Root cause
Radiation Control for Health and Safety Act
Terminated
2020-02-06
Distribution
US Distribution to the states of : AL, SC, OH, MI, PA, and Internationally to Germany and Singapore
Recall number
Z-2777-2017
Recall status
Terminated
CDRH record ID
157833
FDA record created
2017-08-01
Recall event number
77756

Source facts and excerpts are reproduced for research. Dates retain their source meanings. “First observed” describes collection, not FDA publication or product launch.

Recall classification is supplied only when the recall number matches an enforcement record. Recall class and device class are different fields. Several recall records may belong to one recall event.

Useful context

Device classifications

FDA dataset:

Last successful check: Nov 22, 2026

Source classifications may change.

510(k) clearances

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset monthly.

Recall records

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset weekly.

Keep this research moving.

Follow ten competitors and ten product codes. Get matching changes in your dashboard and a weekly brief, for $49/month.

Start a 14-day free trial ↗