Z-2934-2020: Symbia S-Series and Symbia T-Series - Product Usage: Intended use of the device SPECT: To detect or imag

Recall record Z-2934-2020 for Siemens Medical Solutions USA, Inc.. View source facts, labeled dates, and the original FDA record.

FDA identifier
Z-2934-2020
Company in FDA record
Siemens Medical Solutions USA, Inc.
FDA record creation date
Sep 2, 2020
First observed by MedTech Watch
Nov 16, 2026
Latest observed content change
Nov 16, 2026
Recall classification
Class II

Reason stated in the source

This letter is to inform you of the possibility that your Symbia S or Symbia T system(s) may have unintended slow motion of the detectors in specific situations which could pose a potential risk.

Source facts

Action
On 8/14/20 the firm notified their customers via letter of the field action, with the following instructions: How can you help to avoid the potential risk of this issue? You may continue to use your system ensuring to follow all instructions in the Operator Manual. Do not leave the patient unattended at any time while the patient is positioned on the patient bed. Siemens Medical Solutions USA, Inc. 2501 N. Barrington Road Hoffman Estates, IL 60192 USA In the event of an Emergency-Stop, shutdown or power loss the patient should be manually retracted from the gantry using the patient bed pallet handle and release button. In the event of touchpad engagement, confirm there are no system errors reported on the PPM and refer to the instructions in the Operator Manual to address proper patient positioning before continuing. If unintended detector motion is observed, downward pressure from the detector is reported by the patient at any time or the PPM presents a system error (as shown in the picture below), then manually retract the patient from the gantry using the patient bed handle and release button, stop use of the system and contact your customer service representative. Errors or problems that result in patient re-scan or re-dose should be reported to your local Siemens Healthiness representative.
Initiated
2020-08-14
Root cause
Device Design
Terminated
2023-05-01
Distribution
US Nationwide distribution including in the states of Alabama, Alaska, Arizona, California, Colorado, District of Columbia, Florida, Georgia, Idaho, Illinois, Indiana, Iowa, Kansas, Kentucky, Louisiana, Maryland, Massachusetts, Michigan, Minnesota, Missouri, Nebraska, New Jersey, New York, North Carolina, Ohio, Oklahoma, Oregon, Pennsylvania, Puerto Rico, South Carolina, Tennessee, Texas, Utah, Virginia, Washington, West Virginia and Wisconsin.
Recall number
Z-2934-2020
Recall status
Terminated
CDRH record ID
183240
FDA record created
2020-09-02
Recall event number
86262

Source facts and excerpts are reproduced for research. Dates retain their source meanings. “First observed” describes collection, not FDA publication or product launch.

Recall classification is supplied only when the recall number matches an enforcement record. Recall class and device class are different fields. Several recall records may belong to one recall event.

Useful context

Device classifications

FDA dataset:

Last successful check: Nov 22, 2026

Source classifications may change.

510(k) clearances

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset monthly.

Recall records

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset weekly.

Keep this research moving.

Follow ten competitors and ten product codes. Get matching changes in your dashboard and a weekly brief, for $49/month.

Start a 14-day free trial ↗