Z-2964-2026: Halyard LAVH PACK, Model/Catalog Number: USAR053-11 containing Clearify Visualization System (5303907).

Recall record Z-2964-2026 for AVID Medical, Inc.. View source facts, labeled dates, and the original FDA record.

FDA identifier
Z-2964-2026
Company in FDA record
AVID Medical, Inc.
FDA classification date
Aug 14, 2026
First observed by MedTech Watch
Nov 16, 2026
Latest observed content change
Nov 16, 2026
Recall classification
Class II

Reason stated in the source

The kit component was subjected to EO sterilization, contrary to the manufacturer recommendation, which may have led to the component leaking in a kit.

Source facts

Action
Owens & Minor issued an URGENT: MEDICAL DEVICE FIELD CORRECTION notice to its consignees on 7/10/2026 via email. The notice explained the issue, potential risks to health, and requested the following: "ACTIONS TO TAKE: " DO NOT USE AND DISCARD the Clearify Visualization System (Component# 5303907) located in the convenience kit identified in Table 1 above. All other components in the kits may continue to be used. " Add warning labels to affected AVID kits to ensure all users are aware of the actions to take prior to use. A labeling template is enclosed for printing labels which can be affixed on all affected kits and cases in inventory. This label should be applied in a prominently visible location to end-users. The location chosen should not cover any other critical product information found on existing product labeling. Please contact your Sales Representative if pre-printed labels are needed. " Customers (end-users): If you have received product from a distributor, please contact the distributor or your sales representative with any questions you may have. " Distributors: If any of the affected kits identified above were further distributed, please ensure all end-users are appropriately notified and maintain records of effectiveness. " Complete the attached Recall Response Form and return by July 22, 2026."
Initiated
2026-07-10
Root cause
Process control
Distribution
US Nationwide distribution in the state of TX.
Recall number
Z-2964-2026
Recall status
Open, Classified
CDRH record ID
221566
FDA classified
2026-08-14
Recall event number
99443

Source facts and excerpts are reproduced for research. Dates retain their source meanings. “First observed” describes collection, not FDA publication or product launch.

Recall classification is supplied only when the recall number matches an enforcement record. Recall class and device class are different fields. Several recall records may belong to one recall event.

Useful context

Device classifications

FDA dataset:

Last successful check: Nov 22, 2026

Source classifications may change.

510(k) clearances

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset monthly.

Recall records

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset weekly.

Keep this research moving.

Follow ten competitors and ten product codes. Get matching changes in your dashboard and a weekly brief, for $49/month.

Start a 14-day free trial ↗