MQP: Spinal Vertebral Body Replacement Device

FDA product code MQP: Spinal Vertebral Body Replacement Device. View classification details, related manufacturers, 510(k) clearances, and recall records.

FDA classification ↗

Classification details

Product code
MQP
FDA device name
Spinal Vertebral Body Replacement Device
Device class
2
Regulation number
888.3060
Medical specialty
Orthopedic
Review panel
OR

The source does not provide a definition for this entry. Consult the FDA classification and regulation reference for further detail.

Explore orthopedic records →
A product code groups records by FDA classification. It does not establish identical intended uses, commercial availability, or comparative device safety.

Record activity in this scope

280 clearance records and 46 recall records in the covered releases, across 118 source company names and 1 product codes. Dated history runs from Sep 3, 1999 to Oct 29, 2026.

Monthly counts through October 2026
Month510(k) decisionsRecall initiations
October 202500
November 202500
December 202500
January 202610
February 202600
March 202600
April 202600
May 202600
June 202600
July 202620
August 202600
September 202600
October 202610

Product codes represented

Code and FDA device nameClearancesRecalls
MQP · Spinal Vertebral Body Replacement Device28046

All-history totals use the covered releases; monthly counts stop at the last calendar month covered by both sources. Clearances use decision dates; recalls use initiation dates. 0 records lack the required date and are excluded from monthly counts. These are records, not product launches, market share, incidence rates, or comparative safety. Feed filters below do not change this overview.

Clearances and recall records

326 matching records
Device / recordCompany in FDA recordSourceSource date
GIZA Vertebral Body ReplacementZ-2072-2017 · MQPEden Spine Europe SARecallMay 12, 2017FDA record creation date
CAPRI Corpectomy Cage SystemK170055 · MQPK2m510(k)Apr 13, 2017FDA decision date
NuVasive(r) Monolith Corpectomy SystemK170271 · MQPNu Vasive, Incorporated510(k)Mar 30, 2017FDA decision date
Atlas Spine Torque Limiting Handle 6N-m, P/N 70089 Model # ITN-001-000 Used to rotate implant into positionZ-1616-2016 · MQPAtlas Spine, Inc.RecallMay 6, 2016FDA record creation date
Rectangular Corpectomy CageK152460 · MQPAmendia, Inc.510(k)Dec 22, 2015FDA decision date
NuVasive PEEK Corpectomy Railed SystemK151538 · MQPNu Vasive, Incorporated510(k)Sep 4, 2015FDA decision date
NuVasive PEEK Corpectomy SystemK151167 · MQPNu Vasive, Incorporated510(k)Sep 3, 2015FDA decision date
SpineFab Vertebral Body Replacement (VBR) SystemK142005 · MQPOxford Performance Materials510(k)Jul 10, 2015FDA decision date
SynFix-LR Spinal Implant System (Implant Holder for SynFix-LR and surgical technique brochure) The implant holder is used to place the implant…Z-2583-2010 · MQPSynthes USA (HQ), Inc.RecallJun 26, 2015FDA record creation date
NuVasive X-CORE(R) Expandable VBR SystemK142205 · MQPNuvasive, Inc.510(k)Feb 20, 2015FDA decision date
StaXx(R) XD SystemK142996 · MQPSpine Wave, Inc.510(k)Feb 19, 2015FDA decision date
VERTA Corpectomy CageK143490 · MQPCamber Spine510(k)Jan 26, 2015FDA decision date
STGC-LORDOTICK142030 · MQPCardinal Spine, LLC510(k)Jan 23, 2015FDA decision date
CAPRIK142016 · MQPK2m, Inc.510(k)Nov 6, 2014FDA decision date
AIS MODULIFT VBR SYSTEMK142150 · MQPAesculap Implant System, Inc.510(k)Oct 29, 2014FDA decision date
LATERAL VBR SYSTEMK140563 · MQPNu Vasive, Incorporated510(k)Aug 7, 2014FDA decision date
Synthes XRL Medium Trial - Central Body, an instrument used as part of the Synthes XRL System, a vertebral body replacement device. For spinal …Z-1681-2014 · MQPSynthes, Inc.RecallJun 2, 2014FDA classification date
AIS MODULIFT VBR SYSTEMK133802 · MQPAesculap Implant System, Inc.510(k)Apr 17, 2014FDA decision date
TASMIN RK123758 · MQPSignus Medizintechnik GmbH510(k)Jan 14, 2014FDA decision date
PIONEER MAXFUSE VERTEBRAL BODY REPLACEMENT DEVICEK131724 · MQPPioneer Surgical Technology, Inc.510(k)Dec 24, 2013FDA decision date
STAXX(R) SYSTEMK133207 · MQPSpine Wave, Inc.510(k)Dec 6, 2013FDA decision date
T2 XVBR SPINAL SYSTEM, T2 ALTITUDE EXPANDABLE CORPECTOMY DEVICEK131888 · MQPMedtronic Sofamor Danek, Inc.510(k)Sep 23, 2013FDA decision date
Titan Spine Endoskeleton TA Implant products. 2107-0118 18mm Standard Endoskeleton Implant VBR 2107-0120 20mm Standard Endoskeleton Implant VB…Z-0535-2013 · MQPTITAN SPINE, LLCRecallDec 17, 2012FDA classification date
ENDURAMESHK122622 · MQPLucero Medical, LLC510(k)Sep 19, 2012FDA decision date
Enduramesh Corpectomy Spacer System Product Usage: The Enduramesh is a vertebral body replacement system intended for use in the thoracic and …Z-2368-2012 · MQPLucero Medical LLCRecallSep 11, 2012FDA classification date

Manufacturers in these records

Useful context

Device classifications

FDA dataset:

Last successful check: Nov 22, 2026

Source classifications may change.

510(k) clearances

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset monthly.

Recall records

FDA dataset:

Last successful check: Nov 22, 2026

FDA publishes this dataset weekly.

Keep this research moving.

Follow ten competitors and ten product codes. Get matching changes in your dashboard and a weekly brief, for $49/month.

Start a 14-day free trial ↗